Skip to main content

Handheld computers for data entry: high tech has its problems too

Abstract

Background

The use of handheld computers in medicine has increased in the last decade, they are now used in a variety of clinical settings. There is an underlying assumption that electronic data capture is more accurate that paper-based data methods have been rarely tested. This report documents a study to compare the accuracy of hand held computer data capture versus more traditional paper-based methods.

Methods

Clinical nurses involved in a randomised controlled trial collected patient information on a hand held computer in parallel with a paper-based data form. Both sets of data were entered into an access database and the hand held computer data compared to the paper-based data for discrepancies.

Results

Error rates from the handheld computers were 67.5 error per 1000 fields, compared to the accepted error rate of 10 per 10,000 field for paper-based double data entry. Error rates were highest in field containing a default value.

Conclusion

While popular with staff, unacceptable high error rates occurred with hand held computers. Training and ongoing monitoring are needed if hand held computers are to be used for clinical data collection.

Peer Review reports

Background

The use of handheld computers has been increasing steadily in medicine over the last decade. As a data entry tool, handheld computers have a number of advantages over paper-based data collection including reduced paperwork, transcription errors, time and cost [1, 2]. In some clinical settings it has been estimated that the use of a handheld computer can save nurses nearly two hours per day [3]. Handheld computers have been adapted into a variety of research and clinical settings and available software allows integration into many database types. However, studies have not documented the accuracy of data collection using handheld computers. There is an underlying assumption they are better than a paper-based system.

We recently completed a longitudinal prospective randomised controlled trial of 461 palliative patients [4] followed from referral to a specialised palliative care service until death. This trial generated more than 2 million paper-based data entry points. Prior to instituting handheld computers for data collection and entry, we assessed user accuracy. Our aim was to use handheld computers to reduce trial nurse's workload.

Participants, Methods, and Results

An Ethics Committee-approved comparison study was undertaken with 6 trial forms. Staff undertook training on Compaq Pocket PCs model iPAQ H3950. Research nurses completed a traditional paper-based form that was entered into a database by administrative staff in parallel with the same nurse completing an electronic form on the handheld computer. Data were transferred from the handheld computer using a manual cradle. Results of these two methods were compared for discrepancies; the paper form was considered the gold standard.

A total of 2001 data elements from 29 consecutive trial participants were entered using both electronic and paper-based methods. Error rates for data entry using the handheld computers were 67.5 errors per 1000 fields, much higher than the accepted 10 per 10,000 fields for paper-based double data entry[5]. Error rates were highest in fields containing a default value such as a date.

Staff found the handheld computers easy to use and liked using them as a reference tool however they reported discomfort using them for data collection. As reported elsewhere, [6] we experienced a number of technical problems with uploading and downloading data that caused frustration and dissatisfaction. This may have been reduced using a wireless system.

Comment

Rarely have evaluations of user accuracy been undertaken when introducing new technologies for data collection. In contrast to the belief that handheld computers would decrease error rates, we found unacceptably high error rates. This finding has implications for the introduction of electronic data collection for research or clinical purposes without an adequate testing phase.

Error rates need to be monitored if handheld computers are to be used both at the time they are introduced, and in an ongoing way.

References

  1. Saleh KJ, Radosevich DM, Kassim RA, Moussa M, Dykes D, Bottolfson H, Gioe TJ, Robinson H: Comparison of commonly used orthopaedic outcome measures using palm-top computers and paper surveys. Journal of Orthopaedic Research. 1920, 1146-1151.

    Google Scholar 

  2. Shaw S, May V: An Australian agency revolutionizes home care with the palm pilot. Caring. 2004, 23: 30-32.

    PubMed  Google Scholar 

  3. Organizational learning: could it be the key to higher quality and increased revenues?. Healthcare Benchmarks & Quality Improvement. 2002, 9: 37-40.

  4. Abernethy AP, Currow DC, Hunt R, Williams H, Roder-Allen G, Rowett D, Shelby-James T, Esterman A, May F, Phillips PA: A pragmatic 2 x 2 x 2 factorial cluster randomized controlled trial of educational outreach visiting and case conferencing in palliative care-methodology of the Palliative Care Trial [ISRCTN 81117481]. Contemporary Clinical Trials 27(1):83-100,. 2006

    Google Scholar 

  5. Day S, Fayers P, Harvey D: Double data entry: What value, what price?. Controlled Clinical Trials. 1998, 19: 15-24. 10.1016/S0197-2456(97)00096-2.

    Article  CAS  PubMed  Google Scholar 

  6. Chan SS, Chu CP, Cheng BC, Chen PP: Data management using the personal digital assistant in an acute pain service. Anaesthesia & Intensive Care. 2004, 32: 81-6.

    CAS  Google Scholar 

Download references

Acknowledgements

We thank Mr Fred Calbrese and Darron Richardson for their technical assistance and training in the use of the pocket PCs. We would also like to thank Christine Lillie for recruiting the participants into the study as well as all the Southern Adelaide Palliative Services community palliative care nurses for collecting the data for this study. Further, we would like to thank all the GPs, patients and families who generously agreed to participate in this study.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tania M Shelby-James.

Additional information

Competing interests

The author(s) declare that they have no competing interests.

Authors' contributions

TSJ carried out conception and design, obtaining funding, acquisition of data; analysis and interpretation of data and drafting of the manuscript. AA carried out conception and design; analysis and interpretation of data and critical revision of manuscript. AM provided technical advice and design of the data base and critical revision of the manuscript. DC participated in the design of the study, interpretation of the data, critical revision of the manuscript and supervision. All authors read and approved the final manuscript.

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Shelby-James, T.M., Abernethy, A.P., McAlindon, A. et al. Handheld computers for data entry: high tech has its problems too. Trials 8, 5 (2007). https://doi.org/10.1186/1745-6215-8-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1745-6215-8-5

Keywords