3D printing vs traditional workflow for the fabrication of mandibular implant overdentures: study protocol for a mixed-methods cross-over RCT

Abstract

Background

Complete tooth loss is a significant global oral health issue, particularly impacting older individuals with lower socioeconomic status. Computer-assisted technologies enhance oral healthcare access by the elderly. Despite promising in vitro reports on digital denture materials, evidence from randomized clinical trials (RCTs) is lacking to verify their performance. This cross-over RCT will investigate whether 3D-printed implant-retained mandibular overdentures (IMO) are more satisfactory for edentulous seniors than those made through traditional methods.

Methods/design

We will recruit 26 completely edentulous participants (any sex/gender) based on the following eligibility criteria: age ≥ 60 years, no tooth extraction in the past 12 months, two implants in the lower jaw, and need for new dentures in both jaws. Each participant will receive two denture pairs, either manufactured by 3D printing or traditionally, to be worn in a random order. A timeline of 3 months with each denture pair will be considered for outcome assessment (total: 6 months). Patient satisfaction with dentures will be measured by the McGill Denture Satisfaction Questionnaire. We will evaluate other patient-reported outcomes (including oral health-related quality of life) as well as clinician-assessed quality and cost. At the end of the trial, participants will choose which denture pair they wish to keep and interviewed about their experiences with the 3D-printed IMO. The quantitative and qualitative data will be incorporated through an explanatory mixed-methods strategy. A final quantitative assessment will happen after 12 months with the preferred IMO to assess the long-term performance and maintenance needs.

Discussion

This mixed-methods RCT will explore patient experiences with 3D-printed IMOs, aiming to assess the potential for altering clinical practice and dental public health policies. Our results will inform policies by showing whether 3D printing offers comparable outcomes at lower costs, facilitating greater access to oral care for the elderly.

Trial registration

ClinicalTrials.gov, NCT06155630, Registered on 04 December 2023. https://classic.clinicaltrials.gov/ct2/show/NCT06155630

Peer Review reports

Background

Complete tooth loss or edentulism remains one of the most burdensome oral health issues globally. Its prevalence is clustered in elderly populations and tends to remain high for many decades [1]. Edentulism can devastate well-being [2], with depressive symptoms worsening after complete tooth loss [3]. Poorer oral function after tooth loss, including impaired mastication [4], is closely linked to psychosocial discomfort and lower self-esteem [5, 6]. Moreover, edentulism has been shown to have likely systemic implications, as evidenced by its association with disability and earlier mortality in the elderly [7].

Even if implant-retained overdentures restore oral functionality and improve nutrition for the elderly [8,9,10], significant obstacles limit access to such care: (a) public funding for adult oral healthcare is limited, generally excluding prosthetic treatments for most without teeth [11, 12]; (b) high costs of private care, often not reimbursed, disproportionately affect those in lower socioeconomic groups, restricting their access to necessary dental services [13, 14]; (c) the need for multiple clinical visits, sometimes over six, poses challenges in terms of mobility and costs, particularly for those in long-term care or during health crises like pandemics [15, 16].

Computer-assisted technologies can greatly improve access to oral healthcare by the elderly. Fewer appointments for denture treatment, i.e., two to four, instead of five as with the conventional techniques, can reduce patient costs [17]. Patients can receive 3D images of their face with future dentures by internet, thus avoiding a clinical visit [18]. Moreover, digital files can be used to remake the same dentures in the absence of the patient, whereas analogic techniques need a repetition of the original workflow [19].

Among the computer-aided designed and manufactured (CAD/CAM) options for denture fabrication, 3D printing (or additive manufacturing) stands out as a highly promising technology. In comparison to traditional and other CAD/CAM workflows, 3D printed dentures have the potential to minimize material waste while achieving high speed and quality [20]. Even with promising in vitro reports of digital denture materials [21,22,23,24], however, evidence from randomized clinical trials (RCTs) is still missing to verify their clinical performance. Our recent scoping review (search update: March 1, 2023) [25] found no RCT on 3D-printed implant-retained mandibular overdentures (IMO), which have been considered the standard of care for complete edentulism by international consensuses [26, 27].

In addition, treatment success with dentures mostly depends on positive patient experiences. Integrating patient attitudes into the final dentures is vital for favorable results. Thus, patient-reported outcome measures (PROMs) are the core criteria in evaluating denture care, as for many healthcare interventions [23]. Yet, no study has explored patients’ experiences with the CAD/CAM dentures. In other words, it is unclear how patients perceive CAD/CAM dentures and whether they have a satisfactory performance from patients’ perspectives.

Objectives and hypothesis

We aim to conduct the first mixed-methods cross-over RCT to determine the efficacy and patients’ experience with 3D-printed implant-retained mandibular overdentures (IMO), compared to the traditional method, for independently living edentulous seniors who have two implants in the anterior mandible, as purported by the McGill Consensus on Implant Overdentures [26]. Our null hypothesis is that IMOs produced by computer-aided design and 3D printing are as satisfactory to edentulous seniors as those fabricated using traditional methods.

Methods

Design and setting

This mixed-methods cross-over RCT will compare one experimental intervention (CAD/CAM dental prostheses) versus an active comparator (conventional denture fabrication methods). Outcome assessment will take place 3 months after each intervention, up to a total follow-up of 6 months. This will be a single-center RCT, conducted at the Faculty of Dental Medicine and Oral Health Sciences, McGill University (Montreal, Canada). The creation of this report adhered to the guidelines outlined in the Standard Protocol Items: Recommendations for Interventional Trials (SPIRIT) [28]. Figure 1 illustrates the standard protocol items diagram as suggested by SPIRIT, while the SPIRIT checklist for this study is provided in Additional file 1.

Fig. 1
figure 1

The study protocol based on Standard Protocol Items: Recommendations for Interventional Trials (SPIRIT)

Eligibility criteria

This trial will recruit edentulous patients seeking treatment with IMOs and maxillary complete dentures at McGill University.

The inclusion criteria is as follows: (i) elderly according to the age cut-off purported by the World Health Organization (age ≥ 60 years) [29] and living independently; (ii) completely edentulous; (iii) no tooth extraction within the past 12 months; (iv) two implants symmetrically distributed in the anterior mandible for three or more months before the trial interventions; (v) desire to receive both upper denture and lower IMO with new stud attachments; (vi) good understanding of spoken and written English or French; (vii) ability to provide written informed consent.

The exclusion criteria are as follows: (i) severe systemic disease or needing frequent hospitalization (i.e., American Society of Anesthesiologists Physical Status class > II) [30]; (ii) evidence of cognitive or motor impairment; (iii) acute or chronic symptoms of parafunctional or temporomandibular disorders; (iv) intraoral pathologies, either acute, progressive, potentially malignant, or capable to hamper denture fit; (v) signs of endosseous lesions or residual dental structures in panoramic radiographs; (vi) signs of implant failure, including clinical mobility, peri-implant radiolucency, unacceptable bone loss (0.2 mm/year after 1st year, or < 2 mm any time) and/or persistent signs/symptoms of pain, neuropathy, infection, and/or exudate [31].

Participant recruitment

We will recruit participants from the Greater Montreal area by verifying lists of prospective and past patients in our faculty. This will be done directly with the faculty’s clinical staff to reach those patients. Priority will be given to patients treated in recent years who may need to have their old IMOs replaced, e.g., 63 patients from 2010 to 2018 (around eight patients/year). Staff involved in clinical services will mention this study to patients and, if the latter have interest, refer them to our trial coordinator (TC). Patients without implants will be included if they comply with inclusion criteria #4 (two implants in the lower jaw) within the recruitment period.

Recruitment rate will be based on the ability of the researchers to provide treatment rather than participant availability, which is set at three patients/month. Recruiting 37% of the 63 patients available from 2010 to 2018 would reach the planned sample size (n = 26). Participants will be assigned to interventions with the recruitment flow, which will take nine months (from the 5th to the 14th month). Recruitment and care provision to participants will be spread over a 9-month period to reduce seasonal variation in their responses.

Trial interventions

After screening and obtaining patient consent, participants will return to start denture fabrication (Fig. 2). Both denture pairs will be fabricated simultaneously and delivered in random order. Existing attachments will be replaced by Novaloc abutments of adequate cuff height (external margins 1 mm above the mucosa) and yellow/medium retentive matrices.

Fig. 2
figure 2

The trial intervention procedures

Participants will come for a first appointment for scanning their existing dentures, with new abutments (manual torque) and attachment housings in place. The first visit will be the same for both conventional and digital pathways and will consist of scanning the patients’ existing upper complete denture and IMO. The existing dentures will be scanned by using an intraoral scanner (Cerec Primescan, Dentsply Sirona, Charlotte, NC, USA). In the lab, the resulting.stl files will be 3D printed using a Max DLP 3D printer (Asiga, Alexandria, Australia).

In a second clinical appointment, the interim printed dentures will be adjusted with wax for the desired lip support, occlusal plane, occlusal vertical dimension (OVD), and centric relation (CR). Secondary impressions (regular PVS – Examix, GC America, Alsip, IL, USA) will be taken under the intaglio to refine fit, with the new abutments and housings in place. Maxillary and mandibular interim printed dentures will be scanned separately and in occlusion. The face of the patients will also be scanned by a face scanner (Shining 3D face scanner, Shining 3D Ltd.).

In the second lab session,.stl files will be superimposed for the digital pathway. Another software (Exocad Full Denture Module, Exocad GmbH, Darmstadt, Germany) will be used to set teeth and denture bases virtually; virtual dentures will be superimposed to the facial images to estimate final results.

Denture bases will be manufactured by a Max DLP 3D printer with Dentca Denture Base Resin (Dentca Inc., Torrance, USA) at 100 μm/layer and supports on the flanges’ facial surface. A 0.3-mm relief will be applied in the sockets dedicated to receive teeth and attachment housings. Following washing in isopropyl alcohol (5 min), dentures will receive Portrait 3D teeth (Dentsply Sirona, Charlotte, USA), treated by the Fuse 3D Denture Bonding System (Dentsply Sirona). Uncured base resin will be used to lute teeth and cured under UV. Final polymerization will take place in a dental polymerization equipment (Flash, Asiga) for 30 min. Dentures will be finished and polished, and sandblasted (50 μm aluminum oxide) in the attachment sockets.

For the conventional pathway, the second lab session will consist of pouring the impressions (type IV stone), mounting the casts in an Arcon semi-adjustable articulator, removing the printed teeth, and replacing them with wax rim and acrylic tooth setup (Portrait, Dentsply Sirona – same shape, size, and shade used for 3D-printed dentures).

A third appointment will be used for wax try-in for the conventional pathway. For the digital pathway, participants will have a chance to appraise their smile on a computer screen (virtual try-in, done remotely) and request modifications.

Denture bases will be manufactured with conventional heat-polymerized resins, and participants will return for a fourth appointment for delivery, including chairside pick-up of attachments (GC Reline resin; GC America Inc., Alsip, USA). Two short-term adjustments will be scheduled 24–72 h and 7 days after delivery, and then weekly until the dentures are comfortable.

In the fourth appointment, the following will be done for the digital pathway: denture delivery, including abutment insertion (torque: 35 Ncm), chairside attachment pick-up, and first adjustments. Chairside pick-up will use a hard reline resin (GC Reline), to be handled as per manufacturer recommendations.

For both interventions, we expect to adjust most dentures at two post-delivery appointments. In a previous RCT on conventional complete dentures, 10% needed more than four appointments, with a maximum of six appointments for a single participant (total n = 39) [16].

Participants will be scheduled for outcome assessment at 3 months following the delivery of each denture pair. A 3-month period is enough to elicit stable patient perception of existing dentures but will not induce significant wear/degradation of dental biomaterials or poor fit due to changes in intraoral tissues. Moreover, extending each follow-up from 3 to 6 months is not expected to result in changes of ratings of patient satisfaction with received dentures, even if denture adjustments are part of the 3-month period [32, 33].

Participant allocation and minimization of bias

Assignment to either experimental or comparator as the first method will take place immediately after delivery adjustments of both denture pairs. The sequence for the interventions will be decided at the individual level following a list of random numbers (1:1 ratio), according to permuted blocks of varying sizes. Randomization will be performed by the trial coordinator (TC; uninvolved with clinical and follow-up procedures) and will take place at the individual level. The TC will retain a list of fabrication methods per denture pair and identify them as #1 and #2, depending on which will be used first. Random allocation to each intervention sequence will be concealed until both denture pairs are ready for delivery.

The TC will be the only person with access to the randomization codes. It is known that gender influences patient perceptions of received dentures, e.g., elderly women tend to give a higher value to esthetics than their male counterparts [34, 35]. Therefore, the sample will be stratified based on male/female, to analyze possible effects of gender on trial outcomes.

Regarding blinding, participants will be unaware of received interventions, and a researcher uninvolved in the clinical procedures will collect outcome data. Blinding will be lifted only after data collection is complete. Since digital manufacturing may have some specific features (like a subtle staircase topography), blinding effectiveness will be verified at each 3-month follow-up. Participants will answer which denture pair is in use, and to grade their conviction of their response from 0 to 10 (“not at all certain” and “extremely certain,” respectively) [36].

Outcome measures

The primary outcome of this trial will be the general satisfaction of participants with their full dentures, in line with its ultimate goal. In addition, secondary measures will include satisfaction-specific aspects (e.g., chewing ability and esthetics), oral health related quality of life (OHQoL), clinical quality of the dentures, and treatment costs, all based on a public health system perspective.

  1. 1.

    The McGill Denture Satisfaction Questionnaire (MDSQ) [37, 38] will be used to measure overall satisfaction, and satisfaction with specific aspects of the denture—ability to chew, comfort, stability, esthetics (appearance), ability to speak, and ability to clean. Participants will rate their satisfaction on a 100-mm visual analogue scales (VAS) with anchors representing “no satisfaction at all” to “complete satisfaction.” Participants will receive training with VAS before answering the MDSQ. Previous studies have shown good properties for the MDSQ. Besides good internal consistency and reproducibility [38, 39], its ability to discriminate between different clinical conditions denotes good construct validity [38, 40, 41]. At the last follow-up, participants will be asked about which denture pair they prefer, if any, and their reasons.

  2. 2.

    OHQoL: This construct, conceptualized as the “subjective evaluation of the individual’s oral health, functional well-being, emotional well-being, expectations and satisfaction with care, and sense of self” [42], will be assessed by the Oral Health Impact Profile for Edentulous Patients (OHIP-EDENT) questionnaire. OHIP-EDENT is a short version (20 questions) of the original 49-question OHIP (Oral Health Impact Profile) tested specifically with edentulous individuals [43]. Questions can be grouped into subscales, corresponding to domains/dimensions of perceived impact, including functional limitation or social disability. This short version shows good reliability and discriminant validity, akin to the original OHIP [43]. Despite the seven original subscales, a four-domain model based on recent factor analysis studies will be used [44, 45].

  3. 3.

    Clinical denture quality: This trial will use the Functional Assessment of Dentures (FAD) instrument to assess denture quality [46, 47]. FAD is composed of questions about relevant clinical parameters, including dental occlusion/articulation, denture retention, and stability. A single dentist will apply the instrument without removing the dentures from the mouth, which will ensure that s/he cannot see the staircase topography of CAD/CAM fabrication. The color of the denture base materials will be verified at baseline and after 3 months with a Vita EasyShade portable spectrophotometer [48]. Upper dentures will be placed on a black background and three measures will be taken from the center of the palatal vault, at the polished side. Color measures will be expressed according to the CIELCh and CIELab systems. Clinically evident damage (e.g., fractured base or teeth, stains) to denture constituents will be also reported.

  4. 4.

    Cost: Data on both the direct and indirect costs of each fabrication method will be gathered, as done previously [16, 49]. The number of clinical visits for denture fabrication and adjustments will be reported separately, including non-scheduled visits. Total cost per fabrication method will be described in terms of expenses with human resources (time and CAD$) and materials (consumables/equipment use, CAD$). Yearly cost differences, or $(Δ), will be calculated based on the expected lifetime of 5 years for a pair of dentures, by dividing total cost differences by five. After the last follow-up, participants will answer four questions on their willingness-to-pay for each denture pair: (1) If you were to choose A over B, how much are you willing to pay for it? (2) Are you willing to pay the $(Δ) to have A over B? (3) Are you willing to pay the $(Δ) to have A over B by monthly installments (12 months)? (4) Do you think that a public health plan should cover the cost of these treatments? Both or only A or B.

The cost-effectiveness of both methods will be compared by using overall patient satisfaction to measure the effect of interventions. Economic analysis will have the perspective of the public health system of Quebec. All expenditures and resources through all stages of dental care (from clinical exam to denture adjustments) will be included, considering a short-term/3-month time frame. Results will be expressed by the incremental cost-effectiveness ratio (ICER).

  1. 5.

    Adverse effects: All adverse events during the RCT will be recorded at each post-delivery appointment and follow-up. Common events, i.e., mucosal injuries and difficulties with new dentures, will be rated on a three-point ordinal scale [50]. More uncommon (nausea, change in taste and lingering speech difficulties) and rare events (allergy to denture materials) will be reported on a binary scale.

  2. 6.

    Choice of overdenture and patient experiences: A qualitative analysis will be carried out to better understand patients’ perception of CAD/CAM dentures and to find out any emergent themes besides (1) patients’ reasons for choosing a specific denture pair and (2) their experience of using a 3D-printed IMO. By adopting a descriptive approach, individual semi-structured interviews will be carried out to obtain an in-depth understanding of patients’ experiences and preferences [51].

Outcome assessment timeline

  1. 1.

    Screening: The RA will invite potential participants, answer questions, and gather informed consent. The RA will complete a screening form checking eligibility criteria for all approached individuals. Panoramic radiographs will be requested, and recruitment will be conditional based on the results from the imaging (as in the exclusion criteria). As a piloting process, we collect data on gender conformity by two questionnaires, the Conformity to Feminine Norms Inventory-45 and Conformity to Masculine Norms Inventory-30 [52, 53].

  2. 2.

    Baseline: Participants will return for baseline evaluation, intraoral scanning, and collection of sociodemographic information (including gender questionnaires) and medical and dental history (including patient experience with previous dentures). Participants will be asked to complete the MDSQ and OHIP-EDENT, and a dentist with experience in providing full dentures will apply the FAD instrument.

  3. 3.

    Delivery and denture adjustments: Immediately after the end of the delivery appointments, the FAD instrument will be applied for each denture pair (same dentist as on baseline). The adverse effects form will be completed at the same time, as well as during each post-delivery appointment, scheduled or not.

  4. 4.

    First follow-up (3 months): Participants will complete the outcome data questionnaires, the MDSQ and OHIP-EDENT. We will administer both questionnaires with a tablet computer away from the clinical setting. In turn, we will complete the FAD and adverse effects form, as described in the previous paragraph plus the colorimetric evaluation of denture bases.

  5. 5.

    Second follow-up (6 months): Same as in previous time point (questionnaires and colorimetric analysis). At the end of the trial, participants will choose which overdenture they wish to keep. When faced with a choice, one is presented with the choices and the associated costs, which allows for a rationale decision. This is particularly important as dentures are typically not covered by the health care provider. Then, we will conduct individual semi-structured interviews about their experiences with the IMOs. The rich descriptive data obtained by qualitative interviews will help further explicate the quantitative findings. An experienced qualitative researcher will be responsible to conduct the interviews outside of the clinic using an interview guide with open-ended questions. Given the explanatory nature of this mixed-methods design, the interview guide will be created iteratively based on the quantitative outcomes which require further explanation. Each interview will be audio-recorded and transcribed verbatim.

At baseline, we will register time (professional and patient) and materials use for cost analyses. The same procedures will be repeated during every appointment in the trial, scheduled or not.

  1. 6.

    Long-term follow-up: Once participants provide 6-month data and choose the denture pair they wish to keep, we will continue their follow-up. For those participants who have no preference for one specific pair, the last pair used will be kept. Then, we will schedule them for yearly appointments until 5 years, during which the same outcome data will be gathered. In the meantime, participants may contact the research team for unscheduled appointments. Any event such as maintenance and clinical complications, as well as time and procedures done, will be reported as part of collected outcome data.

Sample size estimation

The planned enrollment comprises 26 participants, based on overall patient satisfaction. A minimal important difference of 10 mm (10% of the VAS) was used for the estimation, as done in previous RCTs [41, 54]. A standard deviation of 7.5 mm was chosen for the difference in satisfaction [55]. Considering a 2-sided alpha of 0.01 to compensate for the number of secondary outcomes and a power of 90%, the RCT requires n = 21 for superiority hypothesis testing (i.e., the confidence interval for between-treatment differences would exclude zero) [56]. The final sample size is drawn from including further 20% to the planned n to compensate for possible dropouts; although withdrawals will unlikely pass 10% [41, 55, 57], additional participants may be lost due to aging-related issues (e.g., worsening of systemic diseases, and death).

Adherence to protocol and losses to follow-up

Previous studies by our group reveal high study adherence rates, with > 90% wearing their full dentures over the course of 6 months [41, 57,58,59]. This RCT provides variations of a treatment sought by participants at university clinics, with no major change in their routine. Subsequent follow-ups following the end of this RCT will also elucidate adherence rates for longer periods. As much as possible, we set up the intervention schedule, follow-up, and data collection to resemble traditional oral healthcare procedures. We will also have the RA communicate with the participants using their preferred communication method (e.g., phone, text, e-mail) to verify possible adverse events, such as pain under the denture base, that may require a rapid adjustment visit. Those events and consequent conducts will be reported as part of the outcome variable “5. Adverse effects”.

Analytical plan

Quantitative analysis

We will enter and analyze outcome data in a blind fashion at the end of data collection. The TC will enter data in spreadsheets by randomly coding the interventions as 1 and 2, and the data analyst will be unaware of their meaning until the end of statistical testing. Data will undergo descriptive analysis, with substantial deviations from normality leading to variable transformation. Generalized estimating equations (GEE) will be used to test the effect of interventions, follow-up time, and gender as independent variables, with 95% confidence intervals. Other approaches to assess the primary outcome will involve the inclusion of age, baseline results, and previous denture wearing in separate models, one covariate at a time.

A limitation with regard to GEE is that compared to parametric normal theory methods that necessitate the missing data to be missing at random, GEE methods impose a more stringent condition, requiring the data to be missing completely at random. Our results will be evaluated according to the intention-to-treat principle. In the case of unbalanced missing data among interventions or loss of 5% (n > 2) or more of participants, different strategies will be attempted for imputing primary outcome data, as recommended by Dziura et al. [60]; multiple imputation will be used for patient satisfaction based on least squares regression with at least five datasets. In the case of “missing not at random” (MNAR) data, analyses will be repeated after a baseline-observation-carried-forward approach (i.e., withdrawn participants will be considered as dissatisfied as prior to receiving dentures). A second analysis will be performed with imputed values and cross-checked.

Qualitative analysis

Once the interviews are completed and transcribed, we will use the MaxQDA software for thematic analysis. Transcripts will be cut into meaningful segments and coded. Analysis will initiate by a deductive coding strategy based on the interview questions and the theoretical framework of denture satisfaction [37, 38]. Then, we will proceed by adopting an inductive analysis to add any emerging codes. By an iterative process, the coded segments will be regrouped into relevant themes linked to our study objectives [61, 62]. Methodological rigor will be warranted in the study, including member checking before or during data analysis, to meet trustworthiness, credibility, and transferability [63], that is, the results of the study will be formally or informally discussed with participants. To enhance coding quality, the qualitative researcher and one of the team members will independently code two transcripts chosen at random and then meet to compare/revise the codes if needed. Lastly, the qualitative data will be integrated into quantitative data by an explanatory strategy.

Data management, monitoring, and auditing

Two independent researchers will regularly review the collected data as part of a data monitoring committee. Additionally, McGill University’s Research Ethics Board (REB) Office retains the authority to conduct an independent audit at any point in time.

Risks, participant safety, and trial adherence

This study represents minimal safety risk for participants, since all procedures are comparable with nonsurgical oral healthcare (i.e., clinical exam, intraoral molding). The number of appointments to fabricate and adjust provided dentures is similar to what is done in standard practice, and all materials to be used are approved for patient use by Health Canada. Potential participants will receive a complete explanation of the RCT, including potential risks before invitation to sign the informed consent.

All denture materials are licensed for patient use and sold in Canada and United States. This way, risks associated with treatment are the same expected for minor oral surgery and standard dental implants/dentures. Participants may experience sore spots under the dentures after the placement of retentive components. If this happens, the dentures will be adjusted as necessary. Allergic reactions to dental materials (such as the acrylic mixture used to bond components and denture) are rare but might also occur. We do not expect risks or complications from the x-rays or other exams. This includes data collection and interviews.

We will monitor the participants for the duration of the research appointments. If lower denture breakage happens after installing retentive components during the study timeline, we will fix/repair it at no cost. Any dental treatment need will be managed by our research team or referred to professionals outside our research team. The latter case may arise, for example, if a participant requests more implants to retain their dentures.

Confidentiality

Each participant’s quantitative and qualitative data will be assigned an identification code to ensure confidentiality. The information connecting participants’ identities to the codes will be securely stored in a password-protected file and computer. The final research forms, x-rays, and collected data will be sent to the primary investigator’s office and stored for 25 years for the exclusive objectives of this study and then destroyed. These will be kept secure by a password to which only the principal doctor will have access.

Dissemination and knowledge transfer

Knowledge translation will target (i) the scientific community and (ii) the public health and professional sectors. For the first, the team will publish reports in high-impact dental journals, as done with our previous clinical studies [41, 58]. The group will present results in scientific conferences aiming at dental professionals and researchers, as well as industry professionals, including the General Session of the International Association for Dental Research (IADR). For the second, our team will describe clinical and laboratory procedures as appendices of our scientific papers, besides a short book and YouTube videos, both directed to clinicians. The results of this study will be used to develop continuing education courses and webinars that explain the use of digital dentures based on our experiences and research findings. In addition, we will produce patient education materials, including a brochure and a video that describe the potential benefits and limitations of CAD/CAM technology for denture fabrication.

Discussion

Despite promising results, there is a scarcity of RCTs comparing CAD/CAM to conventional full denture fabrication methods, either implant-retained or conventional [25]. As of March 2018, only two clinical studies have compared full dentures fabricated by CAD/CAM and conventional methods [64]. Both of these studies were non-randomized, with one based on treatment provided by dental students [65] and the other considering surrogate measures [66]. A recent systematic review (updated: October 2019) confirms that CAD/CAM technologies produce dentures that fit intraoral tissues better than conventional methods [67]. That review was restricted to in vitro studies, however. To appraise the state of the current literature regarding digital removable dentures, we re-ran the electronic search strategies of those reviews and found no cross-over clinical trial comparing CAD/CAM to conventional implant-retained dentures. Among those newly published comparative studies on CAD/CAM conventional dentures, two were prospective clinical studies [65, 68], two were retrospective studies [69, 70], one was cross-sectional [71] (all five conducted in student clinics), and one was a non-randomized trial [72], besides one RCT on conventional dentures made with a closed workflow (Dentca) [73]. Besides, no study has so far explored patient experiences with the CAD/CAM dentures. Given the impact of dental prostheses on the oral health of edentulous patients, it is essential to document the clinical and patient-reported performance of digitally fabricated dentures.

Determining the potential benefits of CAD/CAM full dentures for seniors demands high-quality comparative evidence (i.e., RCT). This proposal is the first step to determine the advantages and limitations of that novel technology in treating the elderly with implant overdentures. Utilizing qualitative methods allows for a comprehensive exploration of patients’ experiences, as evidenced by a previous study conducted by our team, which examined the reasons for declining treatment with implant overdentures [38]. Employing a mixed-methods approach will integrate the quantitative findings from the clinical trial by offering an in-depth interpretation of patient perspectives through qualitative methods [58].

Anticipated outcomes are expected to hold significant relevance for clinicians administering implant-assisted treatment to edentate patients. The resulting guidelines and recommendations have the potential to enhance dental prosthetic care for the edentate elderly population, a substantial portion of whom face challenges accessing more intricate treatment modalities.

Results will be important to guide public health systems and practitioners in the adoption of CAD/CAM to streamline denture provision. Better outcomes will enhance the potential access to care by edentulous seniors; government-subsidized programs, such as the recently launched Canadian Dental Care Plan for seniors, will be able to provide IMOs with lower costs and/or fewer restrictions. Less appointments and better infection control will also reduce risks for elders to contract diseases such as COVID-19 and flu-like infections in the dental setting. Possible remote care (virtual try-in of new dentures, ordering remakes at distance) also reduces infection risk. Better knowledge of patient perceptions of CAD/CAM IMOs will highlight the potential barriers and opportunities for using digital prostheses in dental practice. It will also help understand if the CAD/CAM technology has reached its goal of offering a superior/cost-effective treatment.

Trial status

Recruiting since January 2024.

Availability of data and materials

For depositing research data, we might deposit anonymized datasets in the McGill Dataverse repository upon request. According to McGill, all data are stored securely on servers located in Canada. The anonymized data may be published or shared during scientific meetings; however, it will not be possible to identify the participants.

References

  1. Cardoso M, Balducci I, Telles DDM, Lourenço EJV, Nogueira Júnior L. Edentulism in Brazil: trends, projections and expectations until 2040. Cien Saude Colet. 2016;21:1239–46.

    Article  PubMed  Google Scholar 

  2. Gerritsen AE, Allen PF, Witter DJ, Bronkhorst EM, Creugers NH. Tooth loss and oral health-related quality of life: a systematic review and meta-analysis. Health Qual Life Outcomes. 2010;8(1):1–11.

    Article  Google Scholar 

  3. Rouxel P, Tsakos G, Chandola T, Watt RG. Oral health—a neglected aspect of subjective well-being in later life. J Gerontol B Psychol Sci Soc Sci. 2018;73(3):382–6.

    PubMed  Google Scholar 

  4. Meaney S, Connell BO, Elfadil S, Allen F. A qualitative investigation into patients’ perspectives on edentulousness. Gerodontology. 2017;34(1):79–85.

    Article  PubMed  Google Scholar 

  5. Naik AV, Pai RC. Study of emotional effects of tooth loss in an aging north Indian community. Int Sch Res Notices. 2011;2011:395498.

    Google Scholar 

  6. Rodrigues SM, Oliveira AC, Vargas AMD, Moreira AN. e Ferreira EF: Implications of edentulism on quality of life among elderly. Int J Environ Res Public Health. 2012;9(1):100–9.

    Article  PubMed  PubMed Central  Google Scholar 

  7. Holm-Pedersen P, Schultz-Larsen K, Christiansen N, Avlund K. Tooth loss and subsequent disability and mortality in old age. J Am Geriatr Soc. 2008;56(3):429–35.

    Article  PubMed  Google Scholar 

  8. Sharka R, Abed H, Hector M. Oral health-related quality of life and satisfaction of edentulous patients using conventional complete dentures and implant-retained overdentures: an umbrella systematic review. Gerodontology. 2019;36(3):195–204.

    Article  PubMed  Google Scholar 

  9. Suzuki H, Kanazawa M, Komagamine Y, Iwaki M, Jo A, Amagai N, Minakuchi S. The effect of new complete denture fabrication and simplified dietary advice on nutrient intake and masticatory function of edentulous elderly: a randomized-controlled trial. Clin Nutr. 2018;37(5):1441–7.

    Article  PubMed  Google Scholar 

  10. Afrashtehfar KI, Schimmel M. Muscular activity may improve in edentulous patients after implant treatment. Evid-Based Dent. 2016;17(4):119–20.

    Article  PubMed  Google Scholar 

  11. Peres MA, Macpherson LM, Weyant RJ, Daly B, Venturelli R, Mathur MR, Listl S, Celeste RK, Guarnizo-Herreño CC, Kearns C. Oral diseases: a global public health challenge. The Lancet. 2019;394(10194):249–60.

    Article  Google Scholar 

  12. Association CD. The State of oral health in Canada. Canadian Dental Association: Ottawa, Canada; 2017.

    Google Scholar 

  13. Petersen PE, Bourgeois D, Ogawa H, Estupinan-Day S, Ndiaye C. The global burden of oral diseases and risks to oral health. Bull World Health Organ. 2005;83:661–9.

    PubMed  PubMed Central  Google Scholar 

  14. Brothwell DJ, Jay M, Schönwetter DJ. Dental service utilization by independently dwelling older adults in Manitoba, Canada. J Can Dent Assoc. 2008;74(2):161.

    PubMed  Google Scholar 

  15. Kawai Y, Murakami H, Takanashi Y, Lund JP, Feine JS. Efficient resource use in simplified complete denture fabrication. J Prosthodont. 2010;19(7):512–6.

    Article  PubMed  Google Scholar 

  16. Vecchia MPD, Regis RR, Cunha TR, de Andrade IM, da Matta JCS, de Souza RF. A randomized trial on simplified and conventional methods for complete denture fabrication: cost analysis. J Prosthodont. 2014;23(3):182–91.

    Article  PubMed  Google Scholar 

  17. Schweiger J, Stumbaum J, Edelhoff D, Güth J-F. Systematics and concepts for the digital production of complete dentures: risks and opportunities. Int J Comput Dent. 2018;21(1):41.

    PubMed  Google Scholar 

  18. Cristache CM, Totu EE, Iorgulescu G, Pantazi A, Dorobantu D, Nechifor AC, Isildak I, Burlibasa M, Nechifor G, Enachescu M. Eighteen months follow-up with patient-centered outcomes assessment of complete dentures manufactured using a hybrid nanocomposite and additive CAD/CAM protocol. J Clin Med. 2020;9(2):324.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  19. Bidra AS, Taylor TD, Agar JR. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent. 2013;109(6):361–6.

    Article  PubMed  Google Scholar 

  20. Goodacre BJ, Goodacre CJ. Additive manufacturing for complete denture fabrication a narrative review. J Prosthodont. 2022;31(S1):47–51.

    Article  PubMed  Google Scholar 

  21. Srinivasan M, Kamnoedboon P, McKenna G, Angst L, Schimmel M, Özcan M, Müller F. CAD-CAM removable complete dentures: a systematic review and meta-analysis of trueness of fit, biocompatibility, mechanical properties, surface characteristics, color stability, time-cost analysis, clinical and patient-reported outcomes. J Dent. 2021;113:103777.

    Article  CAS  PubMed  Google Scholar 

  22. de Oliveira Limírio JPJ, de Luna Gomes JM, Rezende MCRA, Lemos CAA. Rosa CDDRD, Pellizzer EP: Mechanical properties of polymethyl methacrylate as a denture base: conventional versus CAD-CAM resin–a systematic review and meta-analysis of in vitro studies. J Prosthet Dent. 2022;128(6):1221–9.

    Article  PubMed  Google Scholar 

  23. Wang C, Shi Y-F, Xie P-J, Wu J-H. Accuracy of digital complete dentures: a systematic review of in vitro studies. J Prosthet Dent. 2021;125(2):249–56.

    Article  PubMed  Google Scholar 

  24. Lee C-G, Jin G, Lim J-H, Liu Y, Afrashtehfar KI, Kim J-E. Influence of hydrothermal aging on the shear bond strength of 3D printed denture-base resin to different relining materials. J Mech Behav Biomed Mater. 2024;149:106221.

    Article  CAS  PubMed  Google Scholar 

  25. Jafarpour D, Feine JS, Morris M, Souza RF. Patient-reported outcomes and clinical performance of CAD/CAM removable dentures: a scoping review. Int J Prosthodont. 2023. https://doi.org/10.11607/ijp.8556.

  26. Feine JS, Carlsson GE, Awad MA, Chehade A, Duncan WJ, Gizani S, Head T, Heydecke G, Lund JP, MacEntee M, et al. The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Gerodontology. 2002;19(1):3–4.

    Article  CAS  PubMed  Google Scholar 

  27. Thomason JM, Feine J, Exley C, Moynihan P, Muller F, Naert I, Ellis JS, Barclay C, Butterworth C, Scott B, et al. Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients–the York Consensus Statement. Br Dent J. 2009;207(4):185–6.

    Article  PubMed  Google Scholar 

  28. Moher D, Chan AW. SPIRIT (standard protocol items: recommendations for interventional trials). In: Moher D, Altman DG, Schulz KF, Simera I, Wager E, editors. Guidelines for Reporting Health Research: a user’s manual. Chichester: Wiley; 2014. p. 56–67.

  29. Ageing [https://www.who.int/health-topics/ageing#tab=tab_1]

  30. ASA Physical Status Classification System [https://www.asahq.org/standards-and-guidelines/asa-physical-status-classification-system]

  31. Souza RF. Chapter 16 - Clinical Outcomes. In: Emami E, Feine J, editors. Mandibular implant prostheses - guidelines for edentulous geriatric populations. Springer: Cham; 2018.

    Google Scholar 

  32. Regis RR, Cunha TR, Della Vecchia MP, Ribeiro AB, Silva-Lovato CH, de Souza RF. A randomised trial of a simplified method for complete denture fabrication: patient perception and quality. J Oral Rehabil. 2013;40(7):535–45.

    Article  CAS  PubMed  Google Scholar 

  33. Kawai Y, Murakami H, Shariati B, Klemetti E, Blomfield JV, Billette L, Lund JP, Feine JS. Do traditional techniques produce better conventional complete dentures than simplified techniques? J Dent. 2005;33(8):659–68.

    Article  PubMed  Google Scholar 

  34. Al-Omiri MK, Sghaireen MG, Al-Qudah AA, Hammad OA, Lynch CD, Lynch E. Relationship between impacts of removable prosthodontic rehabilitation on daily living, satisfaction and personality profiles. J Dent. 2014;42(3):366–72.

    Article  PubMed  Google Scholar 

  35. Pan S, Awad M, Thomason JM, Dufresne E, Kobayashi T, Kimoto S, Wollin SD, Feine JS. Sex differences in denture satisfaction. J Dent. 2008;36(5):301–8.

    Article  PubMed  Google Scholar 

  36. Turner JA, Jensen MP, Warms CA, Cardenas DD. Blinding effectiveness and association of pretreatment expectations with pain improvement in a double-blind randomized controlled trial. Pain. 2002;99(1–2):91–9.

    Article  CAS  PubMed  Google Scholar 

  37. Awad MA, Feine JS. Measuring patient satisfaction with mandibular prostheses. Commun Dent Oral Epidemiol. 1998;26(6):400–5.

    Article  CAS  Google Scholar 

  38. de Souza RF, Ribeiro AB, Oates TW, Feine JS. The McGill Denture Satisfaction Questionnaire revisited: exploratory factor analysis of a binational sample. Gerodontology. 2020;37(3):233–43.

    Article  PubMed  Google Scholar 

  39. Caetano TA, Ribeiro AB, Della Vecchia MP, Cunha TR, Chaves CA, de Souza RF. Comparing a tablet computer and paper forms for assessing patient-reported outcomes in edentulous patients. J Adv Prosthodont. 2016;8(6):457–64.

    Article  PubMed  PubMed Central  Google Scholar 

  40. Cerutti-Kopplin D, Emami E, Hilgert JB, Hugo FN, Rivaldo E, Padilha DMP. Predictors of satisfaction with dentures in a cohort of individuals wearing old dentures: functional quality or patient-reported measures? J Prosthodont. 2017;26(3):196–200.

    Article  PubMed  Google Scholar 

  41. de Souza RF, Ribeiro AB, Della Vecchia MP, Costa L, Cunha TR, Reis AC, Albuquerque RF Jr. Mini vs. Standard implants for mandibular overdentures: a randomized trial. J Dent Res. 2015;94(10):1376–84.

    Article  PubMed  Google Scholar 

  42. Sischo L, Broder HL. Oral health-related quality of life: what, why, how, and future implications. J Dent Res. 2011;90(11):1264–70.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  43. Allen F, Locker D. A modified short version of the oral health impact profile for assessing health-related quality of life in edentulous adults. Int J Prosthodont. 2002;15(5):446–50.

    PubMed  Google Scholar 

  44. John MT, Feuerstahler L, Waller N, Baba K, Larsson P, Celebic A, Kende D, Rener-Sitar K, Reissmann DR. Confirmatory factor analysis of the oral health impact profile. J Oral Rehabil. 2014;41(9):644–52.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  45. Souza RF, Leles CR, Guyatt GH, Pontes CB, Della Vecchia MP, Neves FD. Exploratory factor analysis of the Brazilian OHIP for edentulous subjects. J Oral Rehabil. 2010;37(3):202–8.

    Article  CAS  PubMed  Google Scholar 

  46. Anastassiadou V, Naka O, Heath MR, Kapari D. Validation of indices for functional assessment of dentures. Gerodontology. 2002;19(1):46–52.

    Article  CAS  PubMed  Google Scholar 

  47. Corrigan PJ, Basker RM, Farrin AJ, Mulley GP, Heath MR. The development of a method for functional assessment of dentures. Gerodontology. 2002;19(1):41–5.

    Article  CAS  PubMed  Google Scholar 

  48. Al-Qarni FD, Goodacre CJ, Kattadiyil MT, Baba NZ, Paravina RD. Stainability of acrylic resin materials used in CAD-CAM and conventional complete dentures. J Prosthet Dent. 2020;123(6):880–7.

    Article  CAS  PubMed  Google Scholar 

  49. Della Vecchia MP, Leles CR, Cunha TR, Ribeiro AB, Sorgini DB, Muglia VA, Reis AC, Albuquerque RF Jr, de Souza RF. Mini-implants for mandibular overdentures: cost-effectiveness analysis alongside a randomized trial. JDR Clin Trans Res. 2018;3(1):47–56.

    CAS  PubMed  Google Scholar 

  50. de Resende GP, Nogueira TE, Leles CR. Effectiveness of a simplified method for final impression in complete denture treatment: a pragmatic clinical trial. Gerodontology. 2019;36(4):365–73.

    Article  PubMed  Google Scholar 

  51. Lesaffre E, Feine J, Leroux B, Declerck D. Statistical and methodological aspects of oral health research. Chichester: Wiley Online Library; 2009.

  52. Levant RF, McDermott R, Parent MC, Alshabani N, Mahalik JR, Hammer JH. Development and evaluation of a new short form of the Conformity to Masculine Norms Inventory (CMNI-30). J Couns Psychol. 2020;67(5):622–36.

    Article  PubMed  PubMed Central  Google Scholar 

  53. Parent MC, Moradi B. An abbreviated tool for assessing feminine norm conformity: psychometric properties of the conformity to feminine norms inventory-45. Psychol Assess. 2011;23(4):958–69.

    Article  PubMed  Google Scholar 

  54. Ellis JS, Burawi G, Walls A, Thomason JM. Patient satisfaction with two designs of implant supported removable overdentures; ball attachment and magnets. Clin Oral Implants Res. 2009;20(11):1293–8.

    Article  PubMed  Google Scholar 

  55. de Souza RF, Bedos C, Esfandiari S, Makhoul NM, Dagdeviren D, Abi Nader S, Jabbar AA, Feine JS. Single-implant overdentures retained by the Novaloc attachment system: study protocol for a mixed-methods randomized cross-over trial. Trials. 2018;19(1):243.

    Article  PubMed  PubMed Central  Google Scholar 

  56. Julious SA. Sample sizes for clinical trials with normal data. Stat Med. 2004;23(12):1921–86.

    Article  PubMed  Google Scholar 

  57. Cunha TR, Della Vecchia MP, Regis RR, Ribeiro AB, Muglia VA, Mestriner W Jr, de Souza RF. A randomised trial on simplified and conventional methods for complete denture fabrication: masticatory performance and ability. J Dent. 2013;41(2):133–42.

    Article  CAS  PubMed  Google Scholar 

  58. de Souza R, Jabbar A, Jafarpour D, Bedos C, Esfandiari S, Makhoul N, Dagdeviren D, Abi Nader S, Feine J. Single-implant overdentures retained by a novel attachment: a mixed methods crossover randomized clinical trial. JDR Clin Trans Res. 2024;9(1):27–41.

    PubMed  Google Scholar 

  59. Albuquerque IS, Regis RR, de Souza RF, Gurgel KF, Silva PG, Pinto-Fiamengui LMS, Freitas-Pontes KM. Is a two-step impression mandatory for complete denture fabrication on the severely resorbed mandible? A randomized trial on patient perception and denture quality. J Dent. 2020;98:103356.

    Article  CAS  PubMed  Google Scholar 

  60. Dziura JD, Post LA, Zhao Q, Fu Z, Peduzzi P. Strategies for dealing with missing data in clinical trials: from design to analysis. Yale J Biol Med. 2013;86(3):343.

    PubMed  PubMed Central  Google Scholar 

  61. Braun V, Clarke V, Hayfield N, Terry G. Thematic Analysis. In: Liamputtong P, editor. Handbook of Research Methods in Health Social Sciences. Singapore: Springer; 2018. p. 843–60.

  62. Thorogood N, Green J: Qualitative methods for health research. Qualitative methods for health research 2018:1–440.

  63. Sandelowski M. The problem of rigor in qualitative research. ANS Adv Nurs Sci. 1986;8(3):27–37.

    Article  CAS  PubMed  Google Scholar 

  64. Janeva NM, Kovacevska G, Elencevski S, Panchevska S, Mijoska A, Lazarevska B. Advantages of CAD/CAM versus conventional complete dentures - a review. Open Access Maced J Med Sci. 2018;6(8):1498–502.

    Article  PubMed  PubMed Central  Google Scholar 

  65. Kattadiyil MT, Jekki R, Goodacre CJ, Baba NZ. Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting. J Prosthet Dent. 2015;114(6):818–25.

    Article  PubMed  Google Scholar 

  66. AlHelal A, AlRumaih HS, Kattadiyil MT, Baba NZ, Goodacre CJ. Comparison of retention between maxillary milled and conventional denture bases: A clinical study. J Prosthet Dent. 2017;117(2):233–8.

    Article  PubMed  Google Scholar 

  67. Wang C, Shi YF, Xie PJ, Wu JH: Accuracy of digital complete dentures: a systematic review of in vitro studies. J Prosthet Dent 2020.

  68. Srinivasan M, Schimmel M, Naharro M. C ON, McKenna G, Muller F: CAD/CAM milled removable complete dentures: time and cost estimation study. J Dent. 2019;80:75–9.

    Article  PubMed  Google Scholar 

  69. Arakawa I, Al-Haj Husain N, Srinivasan M, Maniewicz S, Abou-Ayash S, Schimmel M: Clinical outcomes and costs of conventional and digital complete dentures in a university clinic: a retrospective study. J Prosthet Dent 2021.

  70. Kim TH, Huh JB, Lee J, Bae EB, Park CJ. Retrospective comparison of postinsertion maintenances between conventional and 3D printed complete dentures fabricated in a predoctoral clinic. J Prosthodont. 2021;30(S2):158–62.

    Article  PubMed  Google Scholar 

  71. Clark WA, Brazile B, Matthews D, Solares J, De Kok IJ. A comparison of conventionally versus digitally fabricated denture outcomes in a university dental clinic. J Prosthodont. 2021;30(1):47–50.

    Article  PubMed  Google Scholar 

  72. Drago C, Borgert AJ. Comparison of nonscheduled, postinsertion adjustment visits for complete dentures fabricated with conventional and CAD-CAM protocols: a clinical study. J Prosthet Dent. 2019;122(5):459–66.

    Article  PubMed  Google Scholar 

  73. Ohara K, Isshiki Y, Hoshi N, Ohno A, Kawanishi N, Nagashima S, Inoue M, Kubo D, Yamaya K, Inoue E, et al. Patient satisfaction with conventional dentures vs digital dentures fabricated using 3D-printing: a randomized crossover trial. J Prosthodont Res. 2022;66:623.

    Article  PubMed  Google Scholar 

  74. TCPS-2: Canadian Institutes of Health Research, Natural Sciences and Engineering Research Council of Canada, and Social Sciences and Humanities Research Council of Canada. Tri-council policy statement: ethical conduct for research involving humans 2014.

Download references

Acknowledgements

Dana Jafarpour is the recipient of Vanier Canada Graduate Scholarship for this protocol.

Funding

This project will be supported by a grant from the ITI Foundation, Switzerland (Grant No. 1744–2023) (Additional file 2).

Author information

Authors and Affiliations

Authors

Contributions

RFS designed and will coordinate the trial. DJ drafted the manuscript and will execute the trial. NE helped to draft this manuscript and will help with the clinical interventions. CB contributed with the study design and is overseeing the qualitative data gathering and analysis. SE contributed with the study design and is overseeing the economic data collection and analysis. SAN is assisting in the prosthetic stages and integration phase/knowledge translation. TS has advised in the data analysis plan. JSF provided important contributions to study design and drafted this manuscript. EZ will assist with knowledge transfer and assessment of material performance. All authors revised and approved the final manuscript.

Corresponding author

Correspondence to Raphael de Souza.

Ethics declarations

Ethics approval and consent to participate

Before enrolling in this trial, all participants will be required to give informed written consent and will be made aware of their right to withdraw at any point. Only in this case will unblinding be permissible. The consent process, study documentation, and the entire trial will adhere to the guidelines outlined in the Tri-Council Policy Statement [74]. The McGill University REB Office approved this protocol under the reference A00-M29-23B (22–07-089). Ethical approval documents can be found in Additional file 3. A version of this protocol has also been registered in the Clinicaltrials.gov registry under the identifier NCT03126942.

Any amendments or modifications to the protocol during the trial will be formally communicated to the REB Office. If approved, these changes will be documented on Clinicaltrials.gov and disclosed to participants, allowing them time to consider continued participation.

Participants will be officially enrolled in the trial only after obtaining a signed informed consent form (Additional file 4). A researcher will explain the study’s aims and nature to each participant before they sign the consent form. It will be clarified that participation is voluntary, and participants are free to withdraw from the study at any time without providing a reason.

Compensation for participants will cover the cost of transportation to data collection appointments, including the baseline assessment. Participants will receive implant overdenture treatment at no cost, along with maintenance during the follow-up period.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1. 

SPIRIT Checklist.

Additional file 2. 

Funding documentation.

Additional file 3. 

Ethical approval document.

Additional file 4. 

Consent form in English.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Jafarpour, D., El-Amier, N., Feine, J. et al. 3D printing vs traditional workflow for the fabrication of mandibular implant overdentures: study protocol for a mixed-methods cross-over RCT. Trials 25, 267 (2024). https://doi.org/10.1186/s13063-024-08097-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13063-024-08097-7

Keywords